11
Citations
4
Health Code
7
Life Safety
2
Citation Dates
0
Enforcement Actions

The most recent comprehensive inspection of BROOKDALE TANGLEWOOD OAKS occurred on April 14, 2026, 11 violations of state standards were cited.

Findings may include citations from previous inspections. A citation is a rule violation noted by a state surveyor; the tables below show each one and whether the facility has recorded a correction date.

Provider Information

Status
Licensed
Type
Type B
Type AResidents must be physically and mentally able to evacuate the facility unassisted, are capable of following directions in an emergency, and do not require routine attendance during nighttime sleeping hours.
Type BResidents may need staff help to evacuate, may not be able to follow directions in an emergency, and may require attendance during nighttime sleeping hours. These facilities are held to stricter staffing and fire safety requirements.
Type CA four-bed facility that meets the state's adult foster care requirements — a small, home-style setting rather than a larger institutional one.
County
Tarrant
Licensee
Brookdale Senior Living INC.
Phone
(817) 922-9559
Accepts Medicare
No
Accepts Medicaid
No
Alzheimer Certification
Yes

Findings

11 citations across 2 dates

Health Code

4 citations
DateCorrectedState Violation Cited
5/22/2025PendingThe facility failed to search the employee misconduct registry and nurse aide registry before hiring to determine if the individual is unemployable.
5/22/2025PendingThe facility failed to search the NAR and EMR annually.
5/22/2025PendingThe facility failed to ensure each resident was free from abuse, neglect, and exploitation.
5/22/2025PendingThe facility failed to follow its internal policies regarding the prevention, detection, and reporting of abuse, neglect, or exploitation.

Life Safety Code

7 citations
DateCorrectedState Violation Cited
4/14/2026PendingThe facility failed to inspect, test, and maintain fire sprinkler system components.
4/14/2026PendingThe facility failed to obtain pressure tests of gas piping in the facility.
4/14/2026PendingThe facility failed to test and maintain an emergency generator that provides power to emergency lighting.
4/14/2026PendingThe facility failed to provide smoke compartmentation where required.
4/14/2026PendingThe facility failed to provide a fire sprinkler system that met the referenced codes and standards.
4/14/2026PendingThe facility failed to protect cooking operations according to the Life Safety Code.
4/14/2026PendingThe facility failed to ensure equipment using natural gas or propane met the referenced codes and standards.

Enforcement Actions

0 records
No enforcement actions found
The state has not taken formal action against this license.