Inspections
The most recent comprehensive inspection of INDIGO ASSISTED LIVING occurred on October 03, 2019, 30 violations of state standards were cited.
Findings
(May include findings from previous inspections)
Health Code
| Date | Corrected | State Violation Cited |
|---|---|---|
| No Health Code violations found | ||
Life Safety Code
| Date | Corrected | State Violation Cited |
|---|---|---|
| 3/25/2022 | 6/27/2023 | The facility failed to ensure the building was structurally sound. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure the building and structure complied with the 2000 edition of the Life Safety Code, NFPA 101. |
| 3/25/2022 | 11/30/2022 | The facility failed to ensure compliance with the National Electrical Code, NFPA 101. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure compliance with licensing standards for assisted living facilities requirements regarding emergency evacuation plans. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure interior walls and/or ceilings were constructed with a material having at least a 20-minute fire rating, or at least 3/8 gypsum board. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide exit signs with emergency power. |
| 3/25/2022 | 11/30/2022 | The facility failed to provide lighting levels in compliance with licensing standards for assisted living facilities. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure the fire alarm and smoke detection system was in compliance with licensing standards for assisted living facilities. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure the installation of the smoke detection system complied with applicable requirements. |
| 3/25/2022 | 11/30/2022 | The facility failed to ensure the smoke detectors were to be tested for sensitivity as required. The facility failed to provide all required fire alarm documentation, including as-built installation drawings, operation and maintenance manuals, and a written sequence of operation, must be available for examination by DADS. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure the required sprinkler system was inspected, tested, and maintained in compliance with NFPA 25. |
| 3/25/2022 | 6/27/2023 | The facility failed to provide the required sprinkler system to meet NFPA 13 or 13R. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure acceptable firefighting service, and/or failed to ensure an approved water supply for firefighting purposes. |
| 3/25/2022 | 6/27/2023 | The facility failed to provide a site and/or building free of fire, health, or physical hazards. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure ramps did not exceed a slope of 1:12, and/or failed to provide all acceptable features of ramps, guardrails, fences, and handrails. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure that all operable windows had insect screens. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide operable windows or powered exhaust that is required for all odor-producing rooms. |
| 3/25/2022 | 6/27/2023 | The facility failed to provide and maintain heating and cooling systems in compliance with licensing standards for assisted living facilities. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure lighting levels were in compliance with licensing standards for assisted living facilities and the Illumination Engineering Society of North America. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide reasonable access and/or necessary equipment for maintenance, testing, and servicing of equipment. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide privacy partitions or curtains at toilets and bathing units used by more than one resident at once. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure tubs and showers had non-slip bottoms or floor surfaces. |
| 3/25/2022 | 11/30/2022 | The facility failed to ensure hot water for resident use was maintained between 100 degrees Fahrenheit and 120 degrees Fahrenheit. |
| 3/25/2022 | 3/25/2022 | The facility failed to ensure the dishwashing area was in compliance with licensing standards for assisted living facilities. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide and/or maintain a commercial range hood and exhaust system in compliance with NFPA 96. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide a clean linen receiving, holding, inspection, sorting or folding, and storage room. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide record drawings of the fire detection and alarm system as installed as required. |
| 3/25/2022 | 6/27/2023 | The facility failed to provide copies of the fire sprinkler system approval, and/or a copy of the hydraulic calculations, alarm configuration, above ground and underground Contractor's Material and Test Certificate proper manufacturing instructions. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide copies of fire alarm and/or sprinkler system service contracts. |
| 3/25/2022 | 3/25/2022 | The facility failed to provide documentation of approval by local authorities or fire marshal, health department or building inspector. |
Enforcement Actions
No enforcement actions found.